| National standard 40kW charging module |
Model number |
YFL100040A National standard charging module |
| Working environment condition |
Operating temperature |
From -40 ° C to +75 ° C, the derating function is required when the temperature is higher than 50 ° C |
| Storage temperature | -40℃~+70℃ | |
| Relative humidity | ≤ 95%RH, no condensation | |
| Cooling mode | Forced air cooling | |
| altitude | 2000m (Derated above 2000m) | |
| Atmospheric pressure | 79kPa~106kPa | |
|
Ac input |
Input format | Three phase+PE |
| Voltage range | 266Vac~456Vac | |
| Not working, able to withstand maximum static voltage | 600Vac | |
| Rated voltage | 380Vac | |
| Maximum input current | 80A | |
| Efficiency (full load) | >95.5% | |
| frequency range | 40Hz~65Hz | |
| THD | ≤5% | |
|
Dc output |
Voltage range | 200Vdc~1000Vdc |
| Constant power output voltage range | 300Vdc~1000Vdc | |
| Current range | 0~134A(Current limiting point can be set) | |
| Rated current | 40A(Setting a current limiting point is required) | |
| Voltage stabilization accuracy | <±0.5% | |
| Steady current accuracy | ≤±1%(Output load 20% rated current~100% current variation) | |
| Load adjustment rate | ≤±0.5% | |
| Grid adjustment rate | ≤±0.1%(Test range is 320V~456V) | |
| Activate overshoot | ≤±3% | |
| Overall dimensions and weight | size | 84mm (height) x 300mm (width) x 437mm (depth) |
| weight | ≤15kg | |
|
other |
communication mode | CAN bus |
|
noise |
<65dB | |
|
Power density |
59.5W/in³ | |
|
Mean time to failure (MTBF) |
>400,000小时 | |
|
authentication |
Cape certification |
The relationship between output power and input voltage

The relationship between output voltage and output current

Ambient temperature