Model
|
YFL-G-DC007A
|
item
|
argument
|
Electrical specification Connection mode
|
|
L、N、PE
|
Input voltage range
|
Single-phase input90VAC to 265VAC
|
Maximum input current
|
32A
|
frequency
|
47Hz-63Hz
|
Maximum output power
|
7kW, constant power above 350V
|
Maximum output current
|
20A
|
Output voltage adjustable range
|
100VDC ~ 750VDC
|
Output leakage current as value
|
<3.5mA@264VAC
|
Output power factor
|
≥0.99@220VAC 50-100%
Load
|
Use environment
|
Operating temperature
|
-20℃ to 55℃
|
humidness
|
Max. 93% (relative humidity)
|
Altitude
|
≤2000m
|
IPLv.
|
Ip54
|
Cooling mode
|
Forced air cooling
|
Mechanism specification
|
Product size
|
380*490*158mm
|
Shell material
|
Sheet metal
|
Net weight of equipment
|
≤18KG (with gun)
|
Output wire
|
5M 9-hole DC gun
|
noise
|
≤60dB(A)
|
Protection mechanism
|
Input test
|
Low voltage, over voltage, leakage protection, over temperature protection
|
Output measurement
|
Over current, over voltage, abnormal draw protection
|
interior
|
Overtemperature, MCU function error detection
|
Status display
|
Status indication
|
LED Flow light
|
Display screen
|
4.3 inches OLED
|
Communication standard
|
Plug and play (standard), swipe card charging (optional), 4G (optional), LEN (optional)
|
enforce standards
|
GB/T 18487.1/.2、GB-T 27930
、 ETSI300132-3(surge current)
|